# Balancing Reserve

Balancing Reserve went live as a new ancillary service in March 2024. Batteries participate in both the positive and negative reserve service.

For more information on batteries doing Balancing Reserve, see [here](https://modoenergy.com/research/balancing-reserve-battery-energy-storage-revenue-may-2024-gb-benchmark).

## How we model Balancing Reserve

Balancing Reserve is included in the dispatch model as a new ancillary service with the following parameters:

* Throughput = 0 (it's a service that pays for availability, not utilization)
* Positive reserve (leading to availability for offers in the BM) is given 90% of the total volume as the negative service has much smaller volume requirements
* The service is (already) saturated, and we assume the same level of saturation as in Frequency Response services
* When providing negative Balancing Reserve, the battery’s headroom needs to be greater than or equal to the contracted volume (MW), and vice versa for positive Balancing Reserve and footroom.
* We also require headroom or footroom to be sufficient to allow a continuous response time at the contracted MW capacity for at least 30 mins. This is a constraint on MWh.

We also allow stacking with other frequency response services, as is permitted in the service rules:

* When providing positive Balancing Reserve (leading to offers or discharging the battery), you can only stack with high-frequency services (which lead to discharging).
* Vice versa for negative Balancing Reserve and low frequency response services.

Assumptions on price are given [here](https://forecastdocs.modoenergy.com/docs/ancillary-service-pricing-copy-1).